In the maintenance of injection molding machine, it is often encountered that the mold cannot be opened. Failure to open the mold is mainly divided into three fault phenomena: no action under pressure, no action under pressure and no action under pressure.
1. There is pressure and no action:
First, check whether the display light of the mold opening valve on the output board is on. If it is on, it means that the computer output is normal and there is a problem with the line from the computer to the mold opening valve. The simplest way is to use a small electric pen to top the mold opening valve and another person to open the mold. If the mold can be opened smoothly after the top, it is to confirm the problem of the line and pull a new line to solve it (circuit problem).
2. There is pressure and mold opening action, but the mold cannot be opened:
It indicates that the output board is normal, and the circuit from the output board to the valve is also normal. There are four situations:
The first is that the fastening screw of the piston of the mold locking cylinder is loose, which causes the screw to be roughened in the cylinder, such as the piston rod is stuck.
The second is mechanical anti-lock. The best way is to remove the locking oil pipe and operate it with a jack, so that the machine will not be damaged.
Third, it is caused by the unsteadiness of the machine stranding (such as burning of the stranding edge, etc.).
The fourth is caused by interference (oil interference and circuit interference). If the valve core is clamped and the mold opening action is required, the oil supply of the oil pump cannot reach the pressure and flow required for mold opening, and of course, the mold cannot be opened; Another kind of interference is the interference of the circuit. For example, the opening wire and the locking wire are connected, because the opening valve and the locking valve work at the same time, and the pressure is about 20 kg, so the mold cannot be opened.
3. No pressure and no action:
However, check that the output board of the computer is normal, there is pressure speed, the opening valve has output, and the computer home page shows it. In this case, we will check other actions, such as the shooting table and the shooting base, which are found to be normal, indicating that this phenomenon belongs to the simplicity of mold opening. Generally, the check is that one person opens the mold, and the other person uses a multimeter to measure whether the coil voltage of the opening valve is about 22-30V, if any, We will temporarily pull the coil of the mold opening valve out of the plug and open the mold for action. If there is pressure but no action, we just need to open the mold cylinder to make sure that there is a piston loose from the piston rod.
Because the oil circuit of the injection molding machine is basically the same, this situation exists in mold opening, and other actions will also be the same. The key of machine repair is to sum up. From this kind of fault, we find that machine repair is simple and complex. In short, it is basically from the four aspects of circuit, hydraulic pressure, oil circuit and machinery. When it comes to complexity, we should generally pay attention to the order of troubleshooting, from simple to complex, that is, circuit, hydraulic, oil circuit and machinery. If the inspection sequence is not appropriate, it will be laborious and time-consuming to repair